Issue description
When initiating a measurement, the magnifying glass selects points on an unexpected plane, making it hard to get the tight measurement.
E.g. When starting or ending a measurement on this shelf the magnifying glass shows the Point cloud on the wrong shelf i.e. the shelf behind (wines) instead of the intended shelf (snacks) is showed.
Root cause
The cause of this is the gaps between the 3D rendered points in IV. When the magnifying glass is used in IV, it displays the point cloud with the settings from the general IV point cloud mode. In general, the smaller the point size, the bigger are the gaps among them, and the likelihood your mouse pointer selects a point behind is higher
Troubleshooting Procedure
To correct this, change the point size in the Perspective appearance for point clouds to eg. 0.25 and try to perform the measurement again.